Festo Контроллер крайних положений SPC11 User Manual
Page 24
1. Installation instructions for the DNCM-...-POT
1-12
Festo P.BE-SPC11-DNCM-EN en 0204NH
Fixed stops ( 9 )
Caution
The use of the whole length of the drive can cause faults.
Fit the fixed stops at 0.5 mm from the drive end position.
If the DNCM-...-POT is operated in conjunction with the
SPC11, external fixed stops will be required. By means of the
fixed stops, the end positions can be set as desired.
Please note
During the teach procedure, a work load is pressed against
the fixed stops at a pressure up to the level of the operat-
ing pressure. Make sure that the fixed stops can withstand
this pressure, in order that the SPC11 can ascertain exactly
the end positions during the teach procedure.
1
1
2
2
1
Cylinder end position
2
Fixed stops
Fig. 1/5: Fixed stops