beautypg.com

Chemglass 75L thru 100L Jacketed User Manual

Page 4

background image

www.cglifesciences.com 

 

 

[email protected]

Stirrer Shaft and Agitator Assembly



















The stirrer shaft and agitators are assembled and installed when shipped. Use the following instructions should you need
to remove or adjust these components.

Components Needed for Stirrer Shaft and Agitator Assembly:
1ea CG-2097

Stirrer Shaft

2ea CG-2095-50 Upper PTFE Agitators
1ea CG-2095-55 Lower PTFE Agitator with Stabilizing Bushing

1. The lower agitator assembly (CG-2095-55) is placed on the end of the stirrer shaft. The sand blasted portion is the

lower end of the stirrer shaft.

2. The upper agitator assemblies (CG-2095-50) slide over the end of the shaft. The stirrer shaft has indents that are

spaced every 10 inches from the bottom for the CG-2095-55 agitator, for positioning. Set screws on the agitator
must be aligned with the indents on the stirrer shaft.






CG-2095-50

Upper Agitator,

2ea Supplied 

CG-2095-55

Lower Agitator,

1ea Supplied 

CG-2097

Stirrer Shaft

CG-2095 Lower

Agitator has Bushing to

Accept a Stabilizing Pin

from Drain Valve