8. MOTOR CONNECTIONS

Step Motors have 4, 6, or 8 wires. To better understand how to connect your step
motor with your R256 Controller, follow the Figures below for the corresponding

motor. NOTE: The dots indicate the starting position of the wires when wound.

4 Lead Wire Motor Connection
Connect one set of windings to the A terminals. Connect the other set of windings to

the B terminals. If the set of windings is unclear, take a pair of wires; use an
ohmmeter to check for continuity. When you find the first two wires that have

continuity, connect it to the A terminals. Connect the other two to the B terminals.

Figure 18: 4 Lead Wire Motor Connection

6 Lead Wire Motor Connection (Half Winding)

Six wire motors can be wound in two ways: Half Winding and Full Winding. Six wire
motors contain a center tap on each of the two windings. For a half-winding

connection, the center tap and one end of the wires are used.

Figure 19: 6 Lead Wire Half Winding Connection

RMS Technologies

Page 21

Version 1.05

R256 Controller Manual