Discharge piping checklist – Goulds Pumps 3796 i-FRAME - IOM User Manual
Page 33

Example: Suction piping equipment
Correct
Incorrect
1
2
3
4
5
1.
Suction pipe sloping upwards from liquid source
2.
Long-radius elbow
3.
Strainer
4.
Foot valve
5.
Eccentric reducer with a level top
1
1.
Air pocket, because the eccentric reducer is not
used and because the suction piping does not slope
gradually upward from the liquid source
Discharge piping checklist
Checklist
Check
Explanation/comment
Checked
Check that an isolation valve is
installed in the discharge line.
The isolation valve is required for:
• Priming
• Regulation of flow
• Inspection and maintenance of the pump
See Example: Discharge piping equipment for
illustrations.
Check that a check valve is installed in
the discharge line, between the
isolation valve and the pump discharge
outlet.
The location between the isolation valve and the
pump allows inspection of the check valve.
The check valve prevents damage to the pump and
seal due to the back flow through the pump, when
the drive unit is shut off. It is also used to restrain
the liquid flow.
See Example: Discharge piping equipment for
illustrations.
If increasers are used, check that they
are installed between the pump and the
check valve.
See Example: Discharge piping equipment for
illustrations.
If quick-closing valves are installed in
the system, check that cushioning
devices are used.
This protects the pump from surges and water
hammer.
Installation (Continued)
Model 3796 i-FRAME Installation, Operation, and Maintenance Manual
31