Replace the wear parts, Replace the throat bushing – Goulds Pumps 3620 - IOM User Manual
Page 71

Maintenance
Pump size
Radial bearing Thrust bearing Bearing
Shaft turn
group
housing bore
M, MX
6312
7312/BECBM
5.1181
2.3628
5.1191
2.3623
L, LX
6313
7313/BECBM
5.5118
2.5597
5.5128
2.5592
XL
6318
7318/BECBM
7.4809
3.5440
7.4820
3.5434
X, XXL, XLX
6320
7320/BECBM
8.4652
3.9377
8.4663
3.9371
XX
6224
7320/BECBM
8.4652
Thrust
Radial
8.4663
3.9377
4.7255
3.9371
7.7249
Bearing housings
Perform these checks when you inspect the bearing housings:
• Check that the bearing housings are very clean, with no burrs.
• Remove all loose and foreign material.
• Check the bearing housing bores against the values in the Ball bearing fits table.
• Repair or replace housings as necessary.
Replace the wear parts
Replace the throat bushing
The throat bushing (125) is held in place by a press fit and tack welds.
1. Remove the bushing:
a) Grind out the tack weld.
b) Press the bushing (125) into the seal chamber of the case (100) and head (184) bore.
2. Install the bushing:
a) Thoroughly clean the bushing fit in the seal chamber of the case (100) and head (184).
Model 3620, API Type BB2 Single Stage / ISO 13709 1st/2nd Ed. / API 610 8th-11th Ed. Installation, Operation, and
69
Maintenance Manual