Suction-piping checklist – Goulds Pumps 3620 - IOM User Manual
Page 30

Installation
Check
Explanation/comment
Checked
Use cushioning devices.
This protects the pump from surges and water hammer
if quick-closing valves are installed in the system.
Alignment criteria for pump flanges
Type
Criteria
Axial
The flange gasket thickness is ±0.03 in. (0.8 mm).
Parallel
Align the flange to be within 0.001 in./in. to 0.03 in./
in. maximum (0.025 mm/mm to 0.8 mm/mm) of the
flange diameter.
Concentric
You can easily install the flange bolts by hand.
Fastening
WARNING:
• Only use fasteners of the proper size and material.
• Replace all corroded fasteners.
• Make sure that all fasteners are properly tightened and that there are no missing fasteners.
Suction-piping checklist
Performance curve reference
CAUTION:
Vary the capacity with the regulating valve in the discharge line. Never throttle the flow from the suction
side. This action can result in decreased performance, unexpected heat generation, and equipment
damage.
Net positive suction head available (NPSH
A
) must always exceed NPSH required (NPSH
R
) as
shown on the published performance curve of the pump.
Suction-piping checks
Check
Explanation/comment
Checked
Check that the distance between
This minimizes the risk of cavita-
the inlet flange of the pump and
tion in the suction inlet of the
the closest elbow is at least five
pump due to turbulence.
pipe diameters.
Check that elbows in general do
—
not have sharp bends.
Check that the suction piping is
The suction piping must never
one or two sizes larger than the
have a smaller diameter than the
suction inlet of the pump.
suction inlet of the pump.
Install an eccentric reducer be-
tween the pump inlet and the
suction piping.
Check that the eccentric reducer
—
at the suction flange of the pump
has the following properties:
• Sloping side down
• Horizontal side at the top
When suction strainers or suction Suction strainers help to prevent
bells are used, check that they are clogging.
at least three times the area of the Mesh holes with a minimum diam-
suction piping.
eter of 1/16 in. (1.6 mm) are
recommended.
If more than one pump operates
This recommendation helps you to
from the same liquid source,
achieve a higher pump perfor-
check that separate suction-piping mance.
lines are used for each pump.
28
Model 3620, API Type BB2 Single Stage / ISO 13709 1st/2nd Ed. / API 610 8th-11th Ed. Installation, Operation, and
Maintenance Manual