beautypg.com

Nilfisk-ALTO RS 850 User Manual

Page 158

background image

ENGLISH

USER MANUAL

44

33014576(4)2008-02 A

RS 850

Problem

Possible cause

Remedy

SUCTION FAN

The suction fan is noisy

Not-lubricated fan bearings

Lubricate

Worn fan bearings

Replace

The motor is faulty

Repair

The suction fan turns but it is not effi cient

The dust fi lters are clogged

Clean

The suction pipe is clogged

Clean

The suction pipe is cut/torn

Replace

The gasket between the suction inlet and the
hopper is broken or misadjusted (replace or
adjust)

Replace/adjust

There is no pressure at the suction system
motor

Adjust the pump pressure

The suction fan does not turn

The control valve assembly is stuck

Repair

The motor is faulty

Replace

Pump failure

Replace

SUCTION INLET AND SKIRT

The suction inlet does not collect debris
effi ciently

The suction inlet position is incorrect

Check the suction inlet and skirt height and
operation

The suction inlet does not lift

Open electrical contact

Repair the electrical system

The control valve assembly is stuck

Repair

The cylinder gaskets are worn

Overhaul the cylinder

There is no pressure at the hydraulic system

Check the pump pressure

The fuse is blown

Replace

Open lifting push-button

Replace

Open joystick safety push-button

Replace

Relay board failure

Overhaul

The solenoid valve is burnt

Replace

SUCTION INLET AND SKIRT

The suction inlet does not lower

The suction fan is off

Activate

There is no pressure at the parachute valve

Check the suction fan control valve assembly
pressure

Lack of pressure in the control valve assembly
solenoid valve

Check the pressure

The fuse is blown

Replace

Deactivated broom switch

Activate

Open lowering push-button

Replace

Open joystick safety push-button

Replace

Relay board failure

Overhaul

The solenoid valve is burnt

Replace

The suction inlet does not shift sideways

Lack of pressure in the cylinder because of
worn gaskets

Overhaul the cylinder

The fuse is blown

Replace

Open left shifting push-button

Replace

Open right shifting push-button

Replace

Open safety push-button

Replace

Relay board failure

Replace

The solenoid valve is burnt

Replace

The skirt opening force is not suffi cient

The skirt opening pressure is incorrect

Adjust the opening pressure

The skirt does not open/close

The switch is deactivated

Activate

The solenoid valve is burnt

Replace