MACHINE PREPARATION
5.
RECHARGING THE BATTERIES
In order to prevent damage to the batteries, avoid over discharging them.
When the battery indicator flashes “0” the batteries should be connected to the
charger immediately.
NOTE: Never leave the batteries completely discharged, even if the machine
is not being used. When recharging the batteries, lift the tank. Every 20
charges check the level of the battery acid (Wet led acid only) and, if
necessary, top up with distilled water.
ATTENTION! For the daily charging routine of the batteries, follow
all of the instructions given by the manufacturer or from their
dealer. Trained staff must carry out all installation and maintenance
operations using the proper safety equipment.
ATTENTION! Danger of gas exhalations and emission of corrosive
liquids
ATTENTION! Fire danger: do not approach with free flames
6. CONNECTING THE BATTERY CONNECTOR
The machine connector (2) has to be connected to the battery connector (1)
7. BATTERY INDICATOR
The battery indicator is digital with 5 positions. The numbers, which appear on
the display, show the approximate charge level.
4 = maximum charge, 3 = charge 3/4, 2 = charge 2/4, 1 = charge 1/4,
0 = (blinking) discharged batteries)
ATTENTION! When the indicator flashes “0” , the brushes
automatically switch off. This is to allow enough time to drive the
machine to the charging area.