NaceCare Solutions ST732 User Manual
Page 17
16
ON COMPLETION OF WORK
Having finished the job and before any type of maintenance is
done:
1. Close the water valve using the lever (1)
2. Lift the brush base using the pedal (2) and lock the lever (3).
3. Lift the squeegee using the pedal (4) and lock the lever (5).
4. Activate the parking brake by pushing the lever (6) downwards.
5. Switch off the solenoid valve switch and the suction motor
switch (1)
6. Switch off the brush motor switch (2)
7. Bring the machine to a suitable place for draining
8. Switch the traction switch in to the neutral position(3)
9. Turn the key (4) into position O (counterclockwise)
10. Activate the parking brake
3
2
1
0
I
4
11. Release the hose placed on the rear panel
12. Unscrew the drain plug and empty the tank
ATTENTION! This operation has to be carried out
using gloves to protect from contact with dangerous
solutions.
13. Take off the brushes and clean them with water (for the brush
disassembly please read further on “DISASSEMBLING THE
BRUSHES”)
1
2
3
4
5
6