DAILY MAINTENANCE
REPLACING THE FRONT SQUEEGEE BLADE
If the front squeegee rubber is worn, a good suction is not achieved and
therefore the machine does not dry well. In that case proceed as follows with
the replacement:
1. Take off the squeegee loosening the register (1)
2. Unscrew the nuts, which hold the front rubber plate of the squeegee.
3. Remove the front rubber plate.
4. Slip off the rubber and replace it
5. Reassemble following these steps in reverse
2
3
1
BRUSH REMOVAL
To remove the brushes, follow these steps:
1. Lift the brush base using the pedal (1) and lock the lever (2)
2. Engage the parking brake (3)
3. Turn the key off and remove it from the switch
4. Remove the battery connector
ATTENTION! Removing the brushes while the machine has
power to it can cause serious bodily injury.
0
I
5. Unhook the splash skirt on the brush base
6. Rotate the brush until it comes off from the brush plate seat as shown in
the figure.