beautypg.com

ADTRAN 234 User Manual

ADTRAN Hardware

background image

TOTAL ACCESS 234 SHDSL NTU

P/N 1200708L1

For more detailed documentation, visit us online at

www.adtran.com

Quick Start Guide

Quick Start Guide, 61200708L1-13B, January 2005

Technical Support 1-888-4ADTRAN or +1-256-963-8716

Copyright © 2005 ADTRAN, All Rights Reserved

C

ONNECT

THE

C

ONSOLE

I

NTERFACE

Before connecting to the Total Access 234 console interface, you will need the following items: VT100
terminal or PC (with VT100 terminal emulation software) and a straight through serial cable with a DB-9
(male) connector on one end and the appropriate interface for your terminal (or PC) on the other.

1. Connect the DB-9 (male) connector of your serial cable to the console port on the rear

panel of the unit.

2. Connect the loose end of the serial cable to the VT100 terminal or PC (with terminal

emulation software).

3. Open a VT100 terminal session to the Total Access 234 using the following settings:

9600 baud, 8 data bits, no parity bits, and 1 stop bit. Press to activate the
ADTRAN Command Line Interface (CLI).

C

ONFIGURE

G

ATEWAY

IP A

DDRESSES

/S

UBNET

M

ASK

Configure the Gateway IP addresses and subnet mask by following
these steps. If you are not sure what IP address to assign, please
contact your network administrator.

1. Enter enable to activate the Enable command security mode.
2. When prompted, enter the enable password (if configured).
3. Enter config terminal to activate the Global configuration mode.
4. Enter bre lan-gw 10.26.12.12 wan-gw 100.26.12.12 mask

255.255.255.0* to assign LAN and WAN Gateway IP addresses

and subnet mask.

*Note: Underlined text represents example entries only. Modify

them to match your configuration.

5. Enter exit to return to the Enable configuration mode.
6. Enter copy running-config startup-config to save the running

configuration to the unit’s non-volatile memory (NVRAM).

NET

ETH

F

EATURES

One integrated EIA-232 configuration port (DCE)

One integrated 10/100BaseT Ethernet port

2-Wire/4-Wire SHDSL interface

WAN Protocol: ATM

Command Line Interface (CLI)

Management - EOC/CLI using Virtual Terminal

Front panel LEDs

Wall mounting available with additional parts

S

PECIFICATIONS

DC Input Power

12 VDC nominal (8.5 VDC min, 18 VDC max); ITU-T standards: G.991.2

Diagnostics & Test

Self-diagnosis; local loopback; remote loopback

EMC Emissions

EN55022:1998 Class B; FCC Part 15 Class B

EMC Immunity, Power
Fault, and Lightning

EN55024:1998; EN61000-3-2; EN61000-3-3; Telstra 1563; K.21 (2004)
Enhanced

Electrical Safety

EN60950; AS/NZS 60950; UL60950 3rd ed.;
CSA C22.2 No. 60950 3rd ed.; IEC 60950 CB Scheme

Telecom

S043.2; G.991.2

Environmental

Operating Temp: 0

o

C to 50

o

C; Storage Temp: -20

o

C to 70

o

C

*Note:

No stacking should be done at 50

o

C. Up to three units can be stacked at room temperature.

Humidity: 95 percent noncondensing

Dimensions

9.3 inches W x 2.1 inches H x 6.1 inches D

Connectors

SHDSL Port: RJ-45; 135 ohms; TNV-3 rated
10/100BaseT Ethernet: RJ-45
Console Port: DB-9 female
Power Input: Kycon KPJ-3S snap & lock or equivalent

Table standoff cannot be used with this unit.