10 DIP Switches

The serial interfaces mode as well as the monitor address can be adjusted via the
DIP switches.

By default, all DIP switches are set to OFF. This means that the monitor is set
to address 0 and RS232 mode.

4 DIP switches are used to set addresses, and 16 addresses can be realized binary
(0 – 15), which means that 16 monitors can be connected via RS485.

Serial Mode

Monitor Addresses

DIP switch 1

Mode

ON

RS485

OFF

RS232 (default)

Address

DIP switch 2

DIP switch 3

DIP switch 4

DIP switch 5

0

OFF

OFF

OFF

OFF

1

ON

OFF

OFF

OFF

2

OFF

ON

OFF

OFF

3

ON

ON

OFF

OFF

4

OFF

OFF

ON

OFF

5

ON

OFF

ON

OFF

6

OFF

ON

ON

OFF

7

ON

ON

ON

OFF

8

OFF

OFF

OFF

ON

9

ON

OFF

OFF

ON

10

OFF

ON

OFF

ON

11

ON

ON

OFF

ON

12

OFF

OFF

ON

ON

13

ON

OFF

ON

ON

14

OFF

ON

ON

ON

15

ON

ON

ON

ON