8 analog in, Analog in, Connection – Beijer Electronics MT 230 Nautic Monitor EN User Manual
Page 37

Interfaces and Functions
Beijer Electronics, MAEN956
37
9.8 Analog IN
Target Application
The analog input can be used for dimming by voltage externally put on. The in-
put dims several monitors at one time.
Alternatively an external potentiometer (approximately 10 kohm - 100 kohm)
can be attached as voltage divider.
Function
10 V = full brightness and 0 V = completely dark if the analog input is activated
by the controller.
Plug
3-pin Phoenix plug with “screw safety lock” RM3,81 for lines to 1.5 mm².
Connection
Connection Data
AVOUT constantly 10 V DC (max. 10 mA) against AGND
AIN 0 V – 10 V against AGND
Pin
Function
Description
1
AVOUT
Analog output voltage
2
AIN
Analog In
3
AGND
Analog GND