9.8 Analog IN
Target Application
The analog input can be used for dimming by voltage externally put on. The in-
put dims several monitors at one time.
Alternatively an external potentiometer (approximately 10 kohm - 100 kohm)
can be attached as voltage divider.
Function
10 V = full brightness and 0 V = completely dark if the analog input is activated
by the controller.
Plug
3-pin Phoenix plug with “screw safety lock” RM3,81 for lines to 1.5 mm².
Connection
Connection Data
AVOUT constantly 10 V DC (max. 10 mA) against AGND
AIN 0 V – 10 V against AGND
Pin
Function
Description
1
AVOUT
Analog output voltage
2
AIN
Analog In
3
AGND
Analog GND