Vaddio ControlVIEW XHD User Manual
Page 16
ControlVIEW XHD
ControlVIEW XHD Manual 341-917 Rev. C
Page 16 of 24
System Menu (continued)
>Wipe
Selection
>Select
Left to Right
Right to Left
Top to Bottom
Bottom to Top
Down Right to Upper Left
Down Left to Upper Right
Upper Right to Down Left
Upper Left to Down Right
All Sides to Center
Left>Center
>Settle Time
>Select
>0.10 to 0.90 seconds (Default is 0.30)
NOTE:
Settle time allows the user to set up the time delay between switching from one input to another. With a lower settle time,
there is a greater chance that video will glitch on the Preview outputs when the video is switched very quickly, and
repeatedly in such a way and speed that is not really practical. In most applications this is not an issue.
TIP:
To avoid the dastardly video glitch or transient hiccup, use the same resolution video feeds (all 1080i or all 720p on the
inputs) and the settle time (the time it takes to acquire the signal, stabilize the video, route the signal and scale the signal,
process it and send it to the program output) can be reduced for a very quick, glitch free production which is ideal for a 3-
camera interview shoot using quick cuts.
>Tally Level
(Default is Active Low)
>Active
High
>Active
Low
>Init Triggers
>Start
Note: Init Triggers must be performed when new trigger devices have been added after initial startup)
>Preset 67-72
>Cam Presets On
Cam Presets Off
Selects only input port without moving camera
>
Cancel
Returns
to
Main
Menu
Figure 9: ControlVIEW XHD Back Panel with I/O Information
Power:
12 VDC, 3A (5.5mm OD x 2.5mm ID)
Video In 1-6:
HD Component (YPbPr ), RGBHV or Y/C or Composite (DE-15 female x 6)
Control In 1-6:
RS-232C (RJ-45 F x 6)
Video Out:
HD Component (YPbPr), RGBHV or Y/C Composite (DE-15 female x 2)
RS-232: DB-9F
RS-232 THRU:
DB-9 M
Triggers (1-24):
14-pin Phoenix type connector (x2)
Triggers (25-72):
DB-25 F (x2)
Tally Outputs:
7-pin Phoenix type connector
Network:
RJ-45 F (available in a future software release)
Link In/Out:
RJ-45 F (x2)