Pre-engineered skid systems, Installation, operation and maintenance manual – Pulsafeeder Pre-Engineered Skid Systems User Manual
Page 23

Pre-Engineered Skid Systems
Installation, Operation and Maintenance Manual
PES00039, Rev. B
Appendix – Table 1
Page 23
Table 1 – Factory Pre-sets for Components
Pump, if furnished with Skid, and System Description
Component Settings at Factory
Pump Data
System
Configuration
Calibration
Column Size
Back Pressure
Valve
Pressure Relief
Valve*
Pulsation
Dampener
Air Pressure**
Size
GPD
PSI
K2
3
300
Standard
200 mL
50 PSI
150 PSI
120 PSI
12
5
250
B2
5
2
6
C2
6
C3
10
33
12
D3
12
F4
20
H4
41
A2
6
150
13
12
B3
12
34
22
D4
22
G4
42
K5
60
H5
76
3
12
100
100 PSI
80 PSI
A3
12
K3
14
4
24
14
24
B4
24
64
30
44
44
E4
44
G5
96
110
110 PSI
H6
120
100
100 PSI
54
30
80
80 PSI
60 PSI
C4
48
50
25 PSI
50 PSI
40 PSI
J7
240
80
HF
(High Flow)
1000 mL
50 PSI
80 PSI
60 PSI
K7
192
50
25 PSI
50 PSI
40 PSI
H7
240
35
20 PSI
35 PSI
25 PSI
H8
600
30
30 PSI
Note:
*Pressure Relief Valve setting at factory is based upon pump and skid components furnished.
You must determine your system pressure limit. If less than the factory pre-set, you must re-set
the Pressure Relief Valve accordingly.
**Pulsation Dampener air pressure values shown are factory pre-sets.
You must re-set the Pulsation Dampener air pressure to 80% of your system pressure or 80% of
the Back Pressure Valve setting, whichever is greater. Never set higher than 120 PSI.