Pulsafeeder Eclipse Model 75 User Manual
Page 51
45
Maximum Sound Levels
Pump Size
Sound Level (dB)
Eclipse Standard/Eclipse Hypo 02
80
Eclipse Standard/Eclipse Hypo 05
81
Eclipse Standard/Eclipse Hypo 12
82
Eclipse Standard/Eclipse Hypo 25
83
Eclipse Standard/Eclipse Hypo 75
85
Eclipse Standard/Eclipse Hypo 125
95
Maximum Flange Loads
Pump Size
Flange Loads lb (N)
Flange Loads Ft-lb (N-m)
Eclipse Standard/Eclipse Hypo 02
25 (111)
10 (13.5)
Eclipse Standard/Eclipse Hypo 05
25 (111)
20 (27)
Eclipse Standard/Eclipse Hypo 12
25 (111)
25 (33)
Eclipse Standard/Eclipse Hypo 25
30 (133)
20 (27)
Eclipse Standard/Eclipse Hypo 75, & 125
50 (222)
25 (34)
Maximum Suction Lift (Dry or Wetted Pump)
Pump Size
Feet (m)
Eclipse Standard/Eclipse Hypo 02
3 (0.9)
Eclipse Standard/Eclipse Hypo 05
3 (0.9)
Eclipse Standard/Eclipse Hypo 12
3 (0.9)
Eclipse Standard/Eclipse Hypo 25
5 (1.5)
Eclipse Standard/Eclipse Hypo 75, & 125
5 (1.5)
NPSH Required
NPSHr = 2 ft (0.6m) at 1750rpm – All Sizes
Vacuum Systems – Flooded Suction
Maximum vacuum of 28 in-Hg (14 psi- gauge) or 0.1mm Hg (Absolute)
Solids Handling Capability
Size: 70 Microns / 0.003 inches / 0.07 mm
Maximum Concentrations: 10%
200 Mesh strainer recommended