10. Place the front cover (item 5) with o-ring onto the assembled pump. Secure the front cover using the six bolts
and washers (items 3, 4) and two nut plates (item 28) as shown. The flat side of the nut plates mate against
the back of the center housing flange. Tighten these bolts to the torque specified in Section 12. Always
tighten fasteners in a progressive “crisscross” pattern.
Figure 30
11. For IEC frame motors only, if it was removed, install the motor adaptor plate (item 31) onto the motor face
using the four bolts and washers (items 29 and 30). Always tighten fasteners in a progressive “crisscross”
pattern.
Figure 31