1 disassembly – Pulsafeeder Eclipse Model 75 User Manual
Page 15
9
6.
Disassembly/Assembly, Eclipse Standard/Eclipse Hypo 02
B
EFORE PERFORMING ANY MAINTENANCE REQUIRING PUMP DISASSEMBLY
,
BE SURE TO RELIEVE
PRESSURE FROM THE PIPING SYSTEM AND
,
WHERE HAZARDOUS PROCESS MATERIALS ARE INVOLVED
,
RENDER THE PUMP SAFE TO PERSONNEL AND THE ENVIRONMENT BY CLEANING AND CHEMICALLY
NEUTRALIZING AS APPROPRIATE
.
W
EAR PROTECTIVE CLOTHING AND EQUIPMENT AS APPROPRIATE
.
6.1 Disassembly
Close all suction and discharge valves.
Disconnect power source to motor.
Flush and drain pump
Remove piping (optional for KOPKit).
NOTE: The can area will not fully drain and will contain some process fluid.
1. Remove the four motor bolts and washers (items 22, 23) and slide the entire pump straight off the motor.
Figure 4
2. Place pump assembly (motor spool down) on the work surface.