Component operation and checks, Programming the watlow heat controller – Power Soak MX-220-H Owner's Manual User Manual
Page 30
29
Component Operation and Checks
Programming the
Watlow
Heat Controller
1. Push "up" and "down" arrows simultaneously for 5 seconds. The display should
read "CnF9”. If not, push the “down” arrow repeatedly until it does.
2. Push and hold the “set” button. The display will read “no”. Change to “YES” by
pushing the “up” arrow. Release the “set” button.
3. The display should read "tA9”. If not, push the “up” arrow repeatedly until it does.
Push and hold the “set” button. Push the “up” arrow repeatedly until the screen goes
blank. Release the “set” button.
4. Press the “down” arrow. The display will read "In”. Push and hold the “set”
button. The display should read “J”. If not, adjust by pushing the “up” arrow.
Release the “set” button.
5. Press the “down” arrow. The display will read "C_F”. Push and hold the “set”
button. The display should read “oF”. If not, adjust by pushing the “up” arrow.
Release the “set” button.
6. Press the “down” arrow. The display will read "rL”. Push and hold the “set”
button. The display should read “114”. If not, adjust by pushing the “up” or
“down” arrow
‡
. Release the “set” button.
7. Press the “down” arrow. The display will read "rh”. Push and hold the “set”
button. The display should read “118”. If not, adjust by pushing the “up” or
“down” arrow. Release the “set” button. Return to step 6 if necessary.
8. Press the “down” arrow. The display will read "Ot1”. Push and hold the “set”
button. The display should read “ALM”. If not, adjust by pushing the “up” arrow.
Release the “set” button.
9. Press the “down” arrow. The display will read "Ot2”. Push and hold the “set”
button. The display should read “hEAt”. If not, adjust by pushing the “up” arrow.
Release the “set” button.
10. Press the “down” arrow. The display will read "dl5P”. Push and hold the “set”
button. The display should read “Ac”. If not, adjust by pushing the “up” arrow.
Release the “set” button.
11. Press the “down” arrow. The display will read "ALtY”. Push and hold the “set”
button. The display should read “Prno”. If not, adjust by pushing the “up” arrow.
Release the “set” button.
‡
If the display will not go to 114, perform step 7 first, then return to step 6.