Heater works – pump does not work, Overload trips, Pump works – heater does not work – Power Soak MX-220-H Owner's Manual User Manual
Page 23: Intermittent running, Pump leaks
22
Heater works – Pump does not work
Look For
Correction
1 Tripped OVERLOAD
Push red RESET bar on OVERLOAD
2 Loose wires
Tighten wires
3 Defective START or STOP switch
Check and replace as necessary
4 Defective CONTACTOR/OVERLOAD
Check and replace as necessary
7 Defective PUMP MOTOR
Check and replace as necessary
Overload trips
Look For
Correction
1 Low voltage to unit
Check with Volt meter while running
2 Debris in PUMP intake
Clean
3 Debris in IMPELLER
Remove PUMP and clean
4 Defective CONTACTOR
Check and replace as necessary
5 Defective OVERLOAD
Check and replace as necessary
6 Defective PUMP MOTOR
If amp draw is greater than 10% of motor rating and all of above check
out, then replace MOTOR
Pump works – Heater does not work
Look For
Correction
1 Loose wires
Tighten wires
2 Defective SWITCH
Check and replace as necessary
3 Defective HEAT ELEMENT
Check and replace as necessary
4 Defective HEAT CONTROL
Check and replace as necessary
5 Defective THERMOCOUPLE
Check and replace as necessary
6 Defective HEAT CONTACTOR
Check and replace as necessary
Intermittent running
Look For
1 See 2,5 under
Pump and Heater do not work
2 See 5, 6 under
Heater Works – Pump does not work
Pump leaks
Look For
Correction
1 PUMP CASING PLUG loose or defective
Tighten or replace
2 Defective PUMP SEAL
Replace