151555 Rev. A 07/12

LOW TEMPERATURE FREEZERS – “NX201WWW” Models

The Hardening and Holding Cabinet has a power cord in the bottom of the cabinet at the right rear
for connection to power. On initial start-up the evaporator fan motors will not start and you cannot
initiate a defrost until the evaporator coil temperature has lowered to 35°F. This is due to the
thermostat. Also, the cabinet comes with a non-adjustable “Front” control to keep the mullion heaters
off until the cabinet temperature has lowered to 10°F.

LEG AND CONDENSATE PAN INSTALLATION FOR TOP MOUNT CABINETS ONLY

1. Screw legs or casters into existing crate mounting holes.


SERVICE INSTRUCTIONS

1. High head pressure and high back pressure:

A. Condenser coil clogged or restricted
B. Condenser fan motor defective
C. Air discharge in rear of cabinet restricted

2. Low back pressure and low head pressure:

A. Restriction in system
B. Refrigerant undercharged
C. Leak in system

3. Pressure normal – cabinet warm:

A. Coil blocked with frost
B. Refrigerant undercharged
C. Control set too warm

4. Cabinet not cycling – coil blocked with frost:

A. Defective temperature controller
B. Refrigerant overcharged
C. Location too hot
D. Condenser clogged
E. Condenser fan motor defective
F. Defrost heater not operating

5. Compressor starts and runs – but cycles on overload:

A. Low voltage
B. Relay defective
C. Overload defective
D. High head pressure