beautypg.com

Bp500, Filtration and ozone, Circulation pump modes – Balboa Water Group BP500 System User Manual

Page 40: Transforming the control of hot tubs

background image

BP500

Transforming the Control of Hot Tubs

40

Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,

834 b2, Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. All material copyright of Balboa Water Group.

Filtration and Ozone

On non-circ systems, Pump 1 low and the ozone generator will run during
filtration. On circ systems, the ozone will run with the circ pump.
The system is factory-programmed with one filter cycle that will run in the
evening (assuming the time-of-day is properly set) when energy rates are often
lower. The filter time and duration are programmable. A second filter cycle can
be enabled as needed.
At the start of each filter cycle, the blower (if there is one) or Pump 2 (if there is
one) will run briefly to purge its plumbing to maintain good water quality.

READY

RANGE FLTR1

JETS

AUX

LIGHT

HEAT

JETS

AUX

LIGHT

HEAT

Circulation Pump Modes

If the system is equipped with a circ pump, it may be configured to work in one
of three different ways:

The circ pump operates continuously (24 hours) with the exception of turning

t

off for 30 minutes at a time when the water temperature reaches 3°F (1.5°C)
above the set temperature (most likely to happen in very hot climates).
The

t

circ pump stays on continuously, regardless of water temperature.

A

t

programmable circ pump will come on when the system is checking

temperature (polling), during filter cycles, during freeze conditions, or when
another pump is on.