Clean-up Cycle

(optional ML400)

When a pump or blower is turned on by a button press, a
clean-up cycle begins 30 minutes after the pump or blower
is turned off or times out. The pump and the ozone generator
will run for one to four hours, depending on the system.
(On some systems, you can change this setting; see User
Preferences section.)

Freeze Protection

ML400

If the temperature sensors within the heater detect a low
enough temperature, then the pump(s) and the blower
automatically activate to provide freeze protection.
The pump(s) and blower will run either continuously or
periodically depending on conditions.
In colder climates, an optional additional freeze sensor may
be added to protect against freeze conditions that may
not be sensed by the standard sensors. Auxiliary freeze
sensor protection acts similarly except with the temperature
thresholds determined by the switch. See your dealer
for details.

Locking Features

ML400

If this panel is used as the main panel, locking features
will not be available. If this panel is used as a remote or
additional panel, it will lock when the main panel is locked.
To unlock this panel, unlock the main panel.
In the same way, the set temperature can be locked and
unlocked by a main panel. When the set temperature is
locked, it cannot be changed from either panel.

Preset Filter Cycles

ML400

On all systems, the pump and the ozone generator will run
during filtration. At the start of each filter cycle, the blower
will run briefly on its highest speed to purge the air channels.
The lowest speed of any other pumps and the mister will
also run briefly. On some circ systems, pump 1 may also run
for the duration of the filter.

(Note: This panel cannot be used to program filter cycles
for systems that are programmed by time rather than
by duration. For these systems, a larger panel is needed
and the following description does not apply.)

The first filter cycle (“day”) begins 6 minutes after the spa is
powered up. The second filter cycle (“night”) begins 12 hours
later. Filter duration is programmable for 1-12 hours (“

”-“

”). The default filter duration can vary from system to

system. To program, press “Temp” then “Jets.” Press “Temp”
to select the filter duration. Press “Jets” to select the number
of filter cycles. The display will show “

” (both “day” and

“night” cycles); “ ” (day cycle only); or “ ” (“night” cycle
only). Press “Temp” to adjust, then press “Jets” to exit the
programming mode. For continuous filtration, use “

” and

”.

Displaying Information About Your Spa ML400

There are several pieces of information about your spa that
can be called up from the panel, but are only needed in
special cases.

To access this information, press “Temp” then “Jets”, then
“Light”. (Each press must be within 3 seconds of the previous
press.) Then press “Temp” until you see “

” on the

display. Press “Jets” to see the SSID (a series of 3 numbers,
such as 100 133 10, which indicates the precise revision of
the software in your spa), followed by the Mach software
version number (such as 2.1), followed by “

” and then

your spa’s network ID number (consisting of both letters and
digits displayed in 5 steps).

If you need to see this series of numbers again, and “

” is

once again on the display, just press “Jets” again.
When done, press the “Light” button (more than once if
necessary) until you see the normal temperature display.

User Preferences ML400

There are several aspects of spa operation that you can
customize using the User Preferences submenu.
Press “Temp” then “Jets”, then “Light”. (Each press must be
within 3 seconds of the previous press.) At this point, if “
” is not showing on the display, press “Temp” until you see

” on the display. Then press “Jets” to enter the User

Preferences submenu.
Once in the User Preferences submenu, press “Temp” to cycle
between these settings:

– Suppress Reminders

When set to “

”, reminders are never

displayed on the panel. When set to “

”,

reminders are displayed on the panel
periodically.