other button to exit.

Locking the Panel

Press “Time” “Jets 1” then “Warm” within 3 seconds.
When locked, the PL “

PL

” light will light. All buttons

are frozen except the “Time” button. To unlock the panel,
press “Time” “Jets 1” then “Cool.”

Locking the Set Temperature

Press “Warm” or “Cool” then “Time,” “Jets 1,” and “Warm”
within 3 seconds to activate the lock. The TL “

TL

” light

will light when the set temperature is locked.
To unlock the set temperature, press “Warm” or “Cool”
then “Time,” “Jets 1” and “Cool.”

Time

When time hasn’t been programmed, the “

” icon

flashes. (Time settings on EL1000 and some EL2000
systems are not preserved in the event of power loss;
time will have to be reprogrammed upon each power up.)

Initial Start-up

When your spa is first actuated, it will go into Priming
mode (after displaying some configuration information).
Please see “Spa Behavior -- Start-up Information” for
additional information.

The Priming mode will last for up to 4 minutes and
then the spa will begin to heat and maintain the water
temperature in the Standard mode. You can exit Priming
mode early by pressing “Warm” or “Cool.”

Mode/Prog

This button is used to switch between standard, economy,
and sleep modes. Press “Mode/Prog” to enter mode
programming, press “Cool” to cycle through to desired
mode (LCD flashes until confirmed), then press “Mode/
Prog” to confirm selection.

Standard mode maintains the desired temperature. Note
that the last measured spa temperature displayed is
current only when the pump has been running for at least
1 minute. The “

” icon will display until the mode

is changed.

Economy mode heats the spa to set temperature only
during filter cycles. The “

” icon will display until

mode is changed. Pressing “Jets 1” while in Economy
mode puts the spa in Standard-In-Economy mode, which
operates the same as Standard Mode, then reverts to
Economy Mode automatically after 1 hour. Both the

” and “

” icons display in this mode.

During this time, a press of the “Mode/Prog” button will
revert to Economy Mode immediately.

Sleep mode heats the spa to within 20°F (11°C) of the set
temperature only during filter cycles. The “

” icon

will display until mode is changed.

Standby Mode

Pressing “Warm” or “Cool” then “Jets 2” will turn off all
spa functions temporarily. This is helpful when changing
a filter. Pressing any button resets the spa. On some
systems the “Jets 1” button will control the pump in
Standby Mode (“Drain Mode”). In this case, press any

Setting the Time

Once the spa has been properly connected the first time (every power
up on the EL1000 and some EL2000 systems), notice the “

” icon

appearing on the screen.

Press

then

Select

the hour by pressing

Press

to exit the time setting procedure and enter the
optional filter cycle programming. (Exits programming
on some EL1000 and some EL2000 systems.)

Time

Time

Press

to exit programming.

Press

to enter.

Select

minutes by pressing

Mode/Prog

Mode/Prog

Time

Time

Mode/Prog

Mode/Prog

Mode/Prog

Mode/Prog

Or

(Each press changes
the time by 1 minute)

Warm

Warm

Cool

Cool

Or

(Each press changes
the time by 1 minute)

Warm

Warm

Cool

Cool

ML700 Panel Operation

Diagnostic Messages section for the ML700 is unique. Refer to the User Guide for additional information.
User Guide for panel ML700 is 40520-99.

Cool

Warm

Time

Mode/Prog

Blower

Jets 2

Light

Jets 1

F2

TL

F1

PL