Index of Error Messages

Error Message List

Error Messages

FRU/Action in Sequence

Struck Key

See “Keyboard or Auxiliary Input Device Check” on page 65

System CMOS checksum bad - Default
configuration used

RTC battery
Run BIOS Setup Utility to reconfigure system, then reboot system.

Real time clock error

RTC battery
Run BIOS Setup Utility to reconfigure system time, then reboot
system.
Main board

Previous boot incomplete - Default configuration
used

“Load Setup Defaults” in BIOS Setup Utility.
RTC batter
Main board.

Invalid System Configuration Data

“Load Setup Defaults” in BIOS Setup Utility.
Main board.

Operating system not found

Enter Setup and see if fixed disk and drive A are properly identified.
Diskette drive
Hard disk drive
Main board.

Error Message List

No beep Error Messages

FRU/Action in Sequence

Power-on indicator turns off and LCD is blank.

Power source (battery pack and power adapter.) See “Power
System Check” on page 66.
Ensure every connector is connected tightly and correctly.
Reconnect the DIMM.
Main board.

Power-on indicator turns on and LCD is blank.

Power source (battery pack and power adapter.) See “Power
System Check” on page 66.
Reconnect the LCD connector
Hard disk drive
LCD cable
LCD inverter
LCD
Main board

Power-on indicator turns on and LCD is blank.
But you can see POST on an external CRT.

Reconnect the LCD connectors.
LCD cable
LCD inverter
LCD
Main board

Power-on indicator turns on and a blinking cursor
shown on LCD during POST.

Ensure every connector is connected tightly and correctly.
Main board