Index of error messages – Acer 2700 User Manual
Page 76
Chapter 4
70
Index of Error Messages
Error Message List
Error Messages
FRU/Action in Sequence
Struck Key
See “Keyboard or Auxiliary Input Device Check” on page 65
System CMOS checksum bad - Default
configuration used
RTC battery
Run BIOS Setup Utility to reconfigure system, then reboot system.
Real time clock error
RTC battery
Run BIOS Setup Utility to reconfigure system time, then reboot
system.
Main board
Previous boot incomplete - Default configuration
used
“Load Setup Defaults” in BIOS Setup Utility.
RTC batter
Main board.
Invalid System Configuration Data
“Load Setup Defaults” in BIOS Setup Utility.
Main board.
Operating system not found
Enter Setup and see if fixed disk and drive A are properly identified.
Diskette drive
Hard disk drive
Main board.
Error Message List
No beep Error Messages
FRU/Action in Sequence
Power-on indicator turns off and LCD is blank.
Power source (battery pack and power adapter.) See “Power
System Check” on page 66.
Ensure every connector is connected tightly and correctly.
Reconnect the DIMM.
Main board.
Power-on indicator turns on and LCD is blank.
Power source (battery pack and power adapter.) See “Power
System Check” on page 66.
Reconnect the LCD connector
Hard disk drive
LCD cable
LCD inverter
LCD
Main board
Power-on indicator turns on and LCD is blank.
But you can see POST on an external CRT.
Reconnect the LCD connectors.
LCD cable
LCD inverter
LCD
Main board
Power-on indicator turns on and a blinking cursor
shown on LCD during POST.
Ensure every connector is connected tightly and correctly.
Main board