background image

Raven X EV-DO for Verizon - User Guide, version 2.34

136

Frequently Asked Questions and Technical Support

Using ALEOS

Using Direct Commands to the internal hardware (use only if the above is
unsuccessful)

TABLE 1.

Provisioning

Command

Description

1

AT*TELNETTIMEOUT=20

(this command and the next is only needed for an
Ethernet connection)

Set telnet timeout in modem to 20 minutes.

2

AT&W

Save the telnet setting.

3

ATI3

Verify ALEOS has established communica-
tion to the internal hardware.

4

If you have the same number for the MIN and MDN:

AT*PROVISION=

MSL,MDN[,SID,NID]

If you have the different numbers for the MIN and
MDN:

AT*PROVISION2=

MSL,MDN,MIN[,SID,NID]

Enter the activation command appropriate
for your type of account. The SID and NID
are optional and only required if your
account type uses them.

TABLE 2.

Prepare for Provisioning

Command

Description

1

AT*TELNETTIMEOUT=20

Set telnet timeout in modem to 20 minutes.

2

AT&W

Save the telnet setting.

3

ATI3

Verify ALEOS has established communica-
tion to the internal hardware.

4

AT\APASSTHRU

Put modem into passthru mode to by-pass
ALEOS.

This will allow direct communication with
the wireless module for programming.
Entering passthru will take 10-15 seconds
and will return an ‘OK’ when it is com-
plete.

**Passthru mode causes first 3 LEDs to
blink simultaneously.

5

ATI0

(the letter “I” and the number “0”)

This will verify you are in Passthru mode.