AR-7EVH Electric Rotisserie with Ventless Hood Operation & Care Manual • 5

I n s t a l l a t I o n

The appliance must be installed by a qualified

service technician. The oven must be properly

grounded in accordance with the National Electrical

Code and applicable local codes.

Plug the unit into a properly grounded receptacle

ONLY, positioning the unit so that the plug is easily

accessible in case of an emergency. Arcing will occur

when connecting or disconnecting the unit unless all

controls are in the “

off

” position.

Proper receptacle or outlet configuration or

permanent wiring for this unit must be installed by

a licensed electrician in accordance with applicable

local electrical codes.
After wiring and power connection has been

completed, turn the main power switch to the “

on

position. The main power switch can be left “

on

for daily use, but should be turned “

off

” when

cleaning or performing maintenance or repairs to

the rotisserie.

AR-7EVH Electric Rotisserie with Ventless Hood Operation & Care Manual • 5

E l E c t r I c a l c o n n E c t I o n

d a n G E r

To avoid electrical shock, this
appliance MUST be adequately
grounded in accordance with local
electrical codes or, in the absence of
local codes, with the current edition
of the National Electrical Code ANSI/
NFPA No. 70. In Canada, all electrical
connections are to be made in
accordance with CSA C22.1, Canadian
Electrical Code Part 1 or local codes.

d a n G E r

ENSURE POWER SOURCE
MATCHES VOLTAGE STAMPED
ON APPLIANCE NAMEPLATE.

d a n G E r

APPLIANCES WITH NO CORD
PROVIDED BY FACTORY MUST
BE EQUIPPED WITH A CORD OF
SUFFICIENT LENGTH TO PERMIT
THE APPLIANCE TO BE MOVED
FOR CLEANING.
ELECTRICAL CONNECTIONS MUST
BE MADE BY A QUALIFIED SERVICE
TECHNICIAN IN ACCORDANCE WITH
APPLICABLE ELECTRICAL CODES.

ElEctrIcal

VOLTAGE

PHASE CYCLE

/

HZ

AMPS

K

W

208 (

AGCY

)

1

60

40.0

8.4

BARE

END

NO

PLUG

240 (

AGCY

)

1

60

38.0

8.9

208 (

AGCY

)

3

60

33.0/ph 8.4

BARE

END

NO

PLUG

240 (

AGCY

)

3

60

32.0/ph 8.9

380-415

(

AGCY

)

3

50

24.0/ph 8.9

NO

CORD

NO

PLUG

380

3

50

22.0/ph 7.5

415

3

50

24.0/ph 8.9

notE

:

CE approved appliances must be

connected to an electrical circuit that is

protected by an external GFCI outlet.

hard wired models:
Hard wired models must be equipped with a

country certified external allpole disconnection

switch with sufficient contact separation.
If a power cord is used for the connection of the

product an oil resistant cord like H05RN or H07RN

or equivalent must be used.

power cord connection:

The side connection

is recommended for all applications. If a bottom

connection is necessary for counter top units, user

will need to provide a cutout in the countertop to

allow the cord to hang freely without crimping.

rEGardInG IntErnatIonal standard unIts:

If the unit is not equipped with flexible cord with

plug, an all-pole country approved disconnection

device which has a contact separation of at least 3mm

in all poles must be incorporated in the fixed wiring

for disconnection. When using a cord without a plug,

the green/yellow conductor shall be connected to the

terminal which is marked with the ground symbol.

If a plug is used, the socket outlet must be easily

accessible. If the power cord needs replacement, use

a similar one obtained from the distributor.

Wire diagrams are located in the inside access panel of the unit.

“WarnIng” rISk OF FIre!

use a ul listed grounding type plug rated 250 Volts,

50 amperes, 1 phase, 3 wire for single phase units and

250 V, 50 a, 3 phase, 4 wire for three phase units. plug

to be selected and installed only by qualified service

personnel. Individual conductors are marked l

1

, l

2

, l

3

when applicable, n when applicable, and g.

For CE approved units: To prevent an electrical

shock hazard between the appliance and other

appliances or metal parts in close vicinity, an

equalization-bonding stud is provided. An

equalization bonding lead must be connected to

this stud and the other appliances / metal parts

to provide sufficient protection against potential

difference. The terminal is marked

with the following symbol.