D E L U X E C O N T R O L O P E R A T I O N
ERROR CODE DISPLAY MESSAGES
probable
cause
Ambient temperature surrounding the
controller is too high or too low.
Controller EEPROM initialization
(
first
time
use
).
Probe shorted.
Probe open.
Exceeded maximum amount of time to
achieve temperature.
Exceeded set temperature by X degrees.
Preset Data Error (EEPROM data error)
Problem with connectors or cable.
TEMPERATURE VERIFICATION
The temperature of the cooking oil/shortening and the temperature set-point can be
verified at any time.
Press the “Temperature” key once to verify the temperature of the oil/shortening.
Press the “Temperature” key twice to verify the set-point temperature.
The fryer control will automatically exit either of these readings after four (4) seconds.
If a defective probe is suspected, measure the temperature of the oil/shortening with a
thermometer. Compare the thermometer reading with temperature shown in the control to
make certain the readings are reasonably close. If there is a wide discrepancy, perform a
complete fryer shutdown and contact Alto-Shaam service.
E-01
AMBIENT
E-02
DEFAULTS
E-10
FIXPROBE
E-20
FIXPROBE
E-30
LOWTEMP
E-31
HITEMP
E-86
SERVICE
NOCOMMS
SERVICE
solution
Adjust the system or the environment so that the ambient
air surrounding the control is above 32°F (0°C) or below
160°F (80°C).
Wait for approximately 30 to 120 seconds. If the message
does not terminate, return the controller to the factory.
Contact Alto-Shaam service.
Contact Alto-Shaam service.
Turn power
OFF
and reset the control.
Turn power
OFF
and allow fryer to cool.
Contact Alto-Shaam service.
Contact Alto-Shaam service.
Check ribbon cable from main board to slave board.
Contact Alto-Shaam service.