4 5 0 ° f – Alto-Shaam FRY TECH ASF-60E User Manual
Page 41

Electric Fryer Operation & Care Manual • 39
D E L U X E C O N T R O L O P E R A T I O N
PROGRAMMING THE CONTROL
“FILTER CNT” The filter count program allows the operator to change the number of processed fry
loads within a range of 5 to 15 before the monitor notifies the operator to service the oil/
shortening. The factory default is set at 15 loads.
THE
“FILTER”
MONITOR
PROGRAM
MUST
BE
ACTIVATED
IN
ORDER
TO
MAKE
THE
“FILTER CNT”
PROGRAM
FUNCTIONAL
.
Press the Up
or Down
arrow keys to scroll until “FILTER CNT” appears in the display. Press
the Right
4
arrow key to enter the program. Display stops flashing. Press the Up
or Down
arrow keys to until the desired number of processed loads appears in the
display. When the desired setting appears, press the Right
4
arrow key to accept the
selection. Display flashes. Press the Down
arrow key to advance the control to the
next programming function.
“MAX TIME”
“MAX TIME”
provides notification when the temperature of the oil is
lower than the set-point temperature. The factory set default is 3 minutes
and should not be adjusted by the operator. Press the down
arrow
key to advance the control to the next programming function.
“HI TEMP”
“HI TEMP”
allows the operator to trigger an automatic fryer shut-down at a specified
oil temperature within a range of 250°F to 450°F (121°C to 232°C). This safety feature is
provided in the event the actual oil temperature exceeds the oil set-point
temperature due to equipment malfunction. The factory default is set at
450°F (232°C).
Press the Up
or Down
arrow keys to scroll until “HI TEMP” appears in the display. Press
the right
4
arrow key to enter the program. Display stops flashing. Press the Up
or
Down
arrow keys to scroll until the desired shut-down temperature appears in the
display. When the desired temperature appears, press the right
4
arrow key to accept the
selection. Press the down
arrow key to advance the control to the next
programming function.
3 : 0 0
Max Time
LoTemp
HOT
4 5 0
° F
Hi Temp
1 5
Filter Cnt