beautypg.com

Karcher HDC advanced User Manual

Page 25

background image

English

25

Fault

Possible cause

Remedy

of whom

Appliance is not running

There is no voltage in the machine. Check electrical mains.

Electrician

Motor protection switch for the con-
trol has been triggered.

Check motor protection switch.

Customer Service

Error code 01 is displayed

Control board defective, green
LEDs are not blinking.

Check control board, replace if necessary.

Customer Service

Pump starts during the stand-
by period and not when the
hand spray gun is opened.

Pressure sensor for high pressure
or cable to pressure sensor defec-
tive.

Replace pressure sensor or cable.

Customer Service

Full pressure does not build up
in the appliance

Flushed the nozzle.

Replace the nozzle.

Operator

Suction site pipe leaking.

Check screw fittings and hoses.

Operator

Safety valve is leaky.

Check the setting; install new washers, if re-
quired.

Customer Service

Overflow valve is leaking or set too
low.

Check valve parts; replace damaged parts;
clean the dirt.

Customer Service

Valve in the pump defective, high-
pressure solenoid valve does not
close.

Replace defective components.

Customer Service

High pressure pump is knock-
ing; manometer is swaying
wildly

Pump is sucking air.

Check suction system and remove leaks.

Operator

Valve plate or valve spring is de-
fective.

Replace defective components.

Customer Service

Advance pump calcified or defec-
tive.

Check advance pump.

Operator

Overflow valve opens and clos-
es continuously during 0 takeo-
ver

Leakage in the high-pressure pipe-
line system or hand spray gun
leaking.

Locate and seal leakage.

Operator

Backflow valve or control piston
seal leaking in overflow valve.

Repair the overflow valve.

Customer Service

Error number 10, 11, 12, 13 is
displayed

Overflow protection switch of the
respective high pressure pump has
been triggered.

Rectify cause for over-loading.

Customer Service

Error number 18, 19, 20, 21 is
displayed

Thermal sensor of the respective
motor has been triggered.

Rectify cause for over-loading.

Customer Service

Error code 26 is displayed

Overflow protection switch of the
advance pressure pump has been
triggered.

Rectify cause for over-loading.

Customer Service

Error code 40 is displayed

The water shortage safeguard in
the swimmer tank has got activat-
ed.

Remove the water shortage.

Operator

Swimmer valve is jammed.

Check swimmer valve for free movement.

Operator

Error code 41 is displayed

The temperature sensor in the
swimmer tank has been activated.

Reduce water infeed temperature.

Operator

Error code 42 is displayed

Leakage in the high-pressure pipe-
line system.

Locate and seal leakage.

Operator

Too many consumer loads open at
the same time.

Close some consumer loads.

Operator

Pressure sensor for high pressure
defective.

Replace pressure sensor.

Customer Service

Error code 43 is displayed

Leakage in the high-pressure pipe-
line system.

Locate and seal leakage.

Operator

Pressure sensor for high pressure
defective.

Replace pressure sensor.

Customer Service

Error code 50 is displayed

Pressure sensor for high pressure
does not transmit signal.

Check pressure sensor, replace if required. Customer Service

Error code 52 is displayed

Temperature sensor does not
transmit signal.

Check temperature sensor, replace if re-
quired.

Customer Service

Error code 14 is displayed

Motor protection switch has been
triggered or frequency inverter not
ready.

Rectify cause for over-loading.

Customer Service

Error code 49 is displayed

Flowmeter does not emit signal.

Check flowmeter, replace if required.

Customer Service