beautypg.com

ROTHENBERGER ROPULS Spülkompressor User Manual

Page 21

background image

ENGLISH

17

In case of power cuts or defect of the transformer fuse, the water will run into the sew age
system during regeneration. In this case immediately close water supply to softener and
contact customer service!

For enquiries, please quote appliance type, number, year, serial no. etc.

What not to do!

Do not touch the head, the cylinders, the cooling fins or the feed line, because during
operation they reach very high temperatures and remain hot even for some time after
the device has been stopped.

Never place flammable materials on or near the compressor.

Never direct the compressed air stream toward people or animals.

Do not run the compressor without an air filter.

Do not use the device in a potentially explosive environment.

The air flow to cool the compressor unit must not be impeded. Therefore, position at
least 50 cm away to obstacles.

2

Technical Data

Compressor:

Pipe connection .......................... R 1" GK-coupling

Max. Flow rate ............................ 5 m³ / h

Water pressure ........................... max. 7 bar

Water temperature ...................... 30 °C

Protection ................................... IP 22

Protection class .......................... I

Suction ....................................... 200 l/min.

Working pressure ........................ Max. 8 bar

Tank capacity ............................. 9,5 litre

Motor output ............................... 1,5 kW

Main supply ................................ ~230 V, 50 Hz

Intermittent .................................. S3 15%

Noise pressure level (L

pA

) ...............77 dB (A) | K

pA

3 dB (A)

Sound power level (L

WA

) .................88 dB (A) | K

WA

3 dB (A)

The noise level during operation can exceed 85 dB (A). Wear ear protection!

Measurements found in compliance with EN 61029-1:2010.

Micro-filter:

Oil retention rate ......................... 99,9%

Particle –backing rate ................. 0,3 µm

New filter element in

Deshydrator ................................

Every 6 months

Suction, air, filter element and compressor cleaning every
month.


3

Scope of delivery

(A)

ROPULS cleaning compressor including GK joint 1”

Accessories: connection consisting of a reinforced hose and 1” joint

Operating manual

Test report

Optional accessories: ROCLEAN Injector