Allied Telesis AT-LMC10ST User Manual
Page 33

AT-LMC10SC and AT-LMC10ST Installation Guide
23
1
RFI Emission
EN55022 Class B
2
Immunity
EN55024
3
Warning: This product requires shielded cables to comply with emission 
and immunity standards. If it is used with unshielded cables, the user may 
be required to take measures to correct the interference problem at their own 
expense.
4
Electrical Safety
EN60950 (TUV), UL1950 (
c
UL
us
)
Safety
5
Laser
EN60825
6
Warning: Class 1 Laser product.
7
Warning: Do not stare into the Laser beam.
At time of installation, the Fiber Optic Lasers comply with FDA Radiation 
Performance Standard 21CFR Subchapter J, applicable at date of 
manufacture. Use of controls or adjustments of performance or procedures 
other than those specified herein may result in hazardous radiation 
exposure.
8
Lightning Danger
Danger: Do not work on equipment or cables during periods of lightning 
activity.
9
Do not block air vents
10
Power to the hub must be sourced only from the adapter.
USA/Canada
Use a UL Listed/CSA Certified AC adapter of DC 12V, 500mA.
Europe - EU
Use TÜV licensed AC adapter of DC 12V, 500mA.
UK
Use a UK Safety Approved AC adapter of DC 12V, minimum 500mA.
11
Operating Temperature: This product is designed for a maximum 
ambient temperature of 40 degrees C.
12
All Countries: Install product in accordance with local and National 
Electrical Codes.