Selecting a site – Allied Telesis AT-FS203 User Manual
Page 26

Installing the Switch
16
❑
Refer to Table 5 for the cabling specifications for the fiber optic port
operating in half-duplex mode.
1. The total distance of the fiber optic lengths cannot exceed the limits stated in the table. Each media converter used
inline within a single collision domain reduces the overall segment length by 40 m (131 ft).
Selecting a Site
Be sure to observe the following requirements when choosing a site for your
switch.
❑
Select a site that is dust-free and moisture-free.
❑
Be sure that the site will allow you to easily access the fiber optic and
twisted pair cables and the power cord.
❑
Use dedicated power circuits or power conditioners to supply reliable
power to the device.
Table 5 100Base-FX Fiber Optic Ports (Half-duplex) For Port 2
1
Number of Media
Converters
Connected Devices
Maximum Distance
One Media Converter Inline
Switch to switch
372 m (1,221 ft)
Workstation to switch
372 m (1,221 ft)
Switch to Class I repeater
137 m (450 ft)
Switch to Class II repeater
185 m (607 ft)
Two Media Converters
Inline
Switch to switch
332 m (1,089 ft)
Workstation to switch
322 m (1, 089 ft)
Switch to Class I repeater
97 m (318 ft)
Switch to Class II repeater
145 m (476 ft)