Table 42: supplicant port parameters – Allied Telesis AT-S63 User Manual
Page 235

AT-S63 Web Browser User’s Guide for AT-9400 Stacks
Section VI: Port Security
235
6. Configure the parameters and click the Apply button: The parameters
are described in this table
Table 42. Supplicant Port Parameters
Parameter
Definition
Auth Period
Specifies the period of time in seconds 
that the supplicant waits for a reply from 
the authenticator after sending an EAP-
Response frame. The range is 1 to 300 
seconds. The default is 30 seconds.
Held Period
Specifies the amount of time in seconds 
the supplicant is to refrain from retrying to 
re-contact the authenticator in the event 
the end user provides an invalid 
username and/or password. After the time 
period has expired, the supplicant can 
attempt to log on again. The range is 0 to 
65,535 seconds. The default value is 60 
seconds.
Max Start
Specifies the maximum number of times 
the supplicant sends EAPOL-Start frames 
before assuming that there is no 
authenticator present. The range is 1 to 
10. The default is 3.
Start Period
Specifies the time period in seconds 
between successive attempts by the 
supplicant to establish contact with an 
authenticator when there is no reply. The 
range is 1 to 60. The default is 30.
User Name
Specifies the username for the switch 
port. The port sends the name to the 
authentication server for verification when 
the port logs on to the network. The 
username can be from be from 1 to 16 
alphanumeric characters (A to Z, a to z, 1 
to 9). Do not use spaces or special 
characters, such as asterisks or 
exclamation points. The username is case 
sensitive.