Figure 31. removing the plastic protector – Allied Telesis x600-48Ts/XP User Manual
Page 64
Chapter 3: Installing the Hardware
64
Note
Do not cable AT-StackXG module until you have prepared the
switch’s Alliedware Plus Operating System software on the x600
Series Switches as explained in the x600 series AlliedWare Plus
5.3.1 Software Reference.
5. Remove the plastic protector from the connector at one end of the
stacking cable.
Figure 31. Removing the Plastic Protector
6. Connect the cable to either Stack Port 1 or Stack Port 2 on the
stacking module and secure by tightening the two captive
thumbscrews.
7. Remove the plastic protector from the connector at the other end of
the stacking cable and connect it to a Stack Port on the stacking
module in the next switch of the stack. A stacking cable must
crossover and connect to a different port on the next stacking module.
Stack Port 1 on a module must connect to Stack Port 2 on the next
module. Do not connect two Stack Port 1 ports or Stack Port 2 ports
together.