At-rps3204 redundant power supply, Figure 12. at-rps3204 redundant power supply unit – Allied Telesis x600-48Ts/XP User Manual
Page 35
x600 Series Layer 3 Gigabit Ethernet Switches Installation Guide
35
AT-RPS3204 Redundant Power Supply
The RPS connector on the rear panel of the switch connects to the
optional AT-RPS3204 Redundant Power Supply module, shown in Figure
12. The unit can provide power to the switch in the event that the switch’s
internal power supply fails.
The AT-RPS3204 Redundant Power Supply module features one pre
installed AT-PWR3202 Power Supply and three empty slots for additional
power supplies. Each power supply can support one x600 switch. When
fully populated with AT-PWR3202 Power Supplies, the AT-RPS3204 unit
can support up to four x600 switches simultaneously.
The AT-RPS3204 Redundant Power Supply module is hot swappable with
the x600 switches. This means that it is safe to connect a powered on AT-
RPS3204 module to an x600 switch (which is also powered on) using a
21-pin D-combo connector cable from the module into the RPS connector
on the x600 switch.
For information about installing an AT-RPS3204 unit, consult the
documentation shipped with the unit.
Figure 12. AT-RPS3204 Redundant Power Supply Unit
The pinouts for the redundant power supply’s 21-pin D-combo port and
connector are described in “RPS 21-pin D-combo Port and Connector
Pinouts” on page 92.
AT-PW
R3204
POWER