10/100/1000Base-T Twisted Pair Ports

This section describes the twisted pair ports on the switches.

Connector Type

The ports are 8-pin RJ-45 connectors that use four pins at 10 or 100 Mbps
and all eight pins at 1000 Mbps. For the pin assignments, refer to “RJ-45
Twisted Pair Port Pinouts” on page 89.

Speed

A port’s speed can be 10, 100, or 1000 Mbps. The speed can be set
automatically through Auto-Negotiation, the default setting, or manually
with the AlliedWare Plus

Operating System Software.

Duplex Mode

A twisted pair port can operate in either half- or full-duplex mode. (Full-
duplex mode is the only mode available when a port is operating at 1000
Mbps.) The twisted pair ports are IEEE 802.3u-compliant and Auto-
Negotiate the duplex mode setting.

You can disable Auto-Negotiation on one or all of the switch ports so that
you can set the duplex mode manually through the AlliedWare Plus

Operating System Software.

Note

In order for a switch port to successfully Auto-Negotiate its duplex
mode with a 10 or 100 Mbps end node, the end node must be
configured for Auto-Negotiation. Otherwise, a duplex mode
mismatch can occur. A switch port using Auto-Negotiation defaults
to half-duplex if it detects that the end node is not using Auto-
Negotiation. This results in a mismatch if the end node is operating
at a fixed duplex mode of full-duplex.

To avoid this problem when connecting an end node with a fixed
duplex mode of full-duplex to a switch port, use the AlliedWare Plus

Operating System Software to disable Auto-Negotiation on the port
and set the port speed and duplex mode manually.

Please be aware that disabling Auto-Negotiation will also disable
Auto-MDI/MDIX and the port’s wiring configuration defaults to the
MDI-X setting. This setting can be configured with the AlliedWare
Plus

Operating System Software.

Maximum

Distance

The ports have a maximum operating distance of 100 meters (328 feet).