Store and forward, Backpressure and flow control, Store and forward backpressure and flow control – Allied Telesis AT-GS900/8 User Manual
Page 24

Chapter 1: Product Description
24
end-node can both receive and transmit data simultaneously, the end-
node is said to be operating in full-duplex mode. Naturally, an end-node
capable of operating in full-duplex can handle data much faster than an
end-node that can only operate in half-duplex mode.
The twisted pair ports on the AT-GS900/8 switch can operate in half- or
full-duplex mode for 10/100 Mbps and full-duplex for 1000 Mbps. It is IEEE
802.3u-compliant and uses Auto-Negotiation to set the duplex mode or
you automatically.
Store and
Forward
The AT-GS900/8 switch uses store and forward as the method for
receiving and transmitting frames. When a Ethernet frame is received on a
switch port, the switch does not retransmit the frame from the destination
port until it has received the entire frame and stored the frame in a port
buffer. It then examines the frame to determine if it is a valid frame. Invalid
frames, such as fragments or runts, are discarded by the switch. This
process insures that only valid frames are transmitted from the switch
ports and that damaged frames are not propagated on your network.
Backpressure and
Flow Control
To maintain the orderly movement of data between the end-nodes, an
Ethernet switch may periodically need to signal an end-node to stop
sending data. This can occur under several circumstances. For example, if
two end-nodes are operating at different speeds, the switch, while
transferring data between the end-nodes, might need to instruct the faster
end-node to stop transmitting data to allow the slower end-node to catch
up. An example of this would be when a server operating at 1000 Mbps is
sending data to a workstation operating at only 100 Mbps.
How a switch signals an end-node to stop transmitting data differs
depending on the duplex mode of the end-node and switch port. A twisted
pair port operating in half-duplex mode stops an end-node from
transmitting data by forcing a collision. A collision on an Ethernet network
occurs when two end-nodes attempt to transmit data using the same data
link at the same time. A collision causes an end-node to stop sending
data, wait for a brief period of time, and then retransmit the same data.
Once the switch is ready to receive data again, the switch stops forcing
collisions. This is referred to as backpressure.
A port operating in full-duplex mode uses PAUSE frames, as specified in
the IEEE 802.3x standard, to stop the transmission of data from an end-
node. Whenever the switch wants an end-node to stop transmitting data, it
issues this frame. The frame instructs the end-node to cease transmission
for a period of time specified within the frame. The switch continues to
issue PAUSE frames until it is ready again to receive data from the end-
node. This is referred to as flow control.