F. Determined the length of (8) BX cable and add about 8”(tbd) for the stripping purposes. Cut the required length of the cable. Trim away the
insulation. Push the exposed wires (hot, neutral and ground) through the anti-short bushing and slide this bushing all the way down to the exposed
wires until it is snug up against the armor.
G. Attach BX cable to the housing with a (7) cable connector. Secure the connection with a clamp.
H. Follow the directions below for Mounting then proceed to Hardwire Installation Completion.
4.
Link to Fixture Installation
(Skip this step if using Hardwire or Cord to Outlet Installation.)
A. First fixture can be Corded or Hardwired
B. Second fixture must be located within 12” of first fixture.
C. A Maximum of 560 Total Watts can be Linked. (28 Lamps x 20Watts = 560 Total Watts)
D. Make sure power is off to all fixtures.
E. Connect the Linking cord (6) to the “Out” connector in the first fixture and to the “In” connector of the second fixture. The connectors only fit one
way. Do not force the connections they should snap in easily.
F. Follow directions in Mounting and Lamping Section.
G. Once Mounting and Lamping are completed, energize first fixture.
Note:
Injury to persons and damage to the mounting surface may result if the fixture or mounting hardware is pulled from the mounting location. To
reduce the possibility of such injury, be sure to mount the fixture only on a surface that is mechanically, structurally sound.
5. Mounting
A. Using captive screw hole locations for mounting the fixture, position the fixture in location intended for mounting. Mark hole locations by using
the screw-holes as a guide. Drill suitable holes in the marked positions. Mount the housing to desired surface with the (4) captive screws .
6. Hardwiring Installation Completion
A. Connect the Green ground input supply wire to the fixture Green ground wire. Do this by
inserting it into the open hole in the push-in wire connector (included) that is attached to the
Green ground wire in the fixture.
B. Connect the White input supply wire to the fixture White wire. Do this by inserting it into
the open hole in the push-in wire connector (included) that is attached to the White wire in
the fixture.
C. Connect the Black input supply wire to the fixture Black wire. Do this by inserting it into
the open hole in the push-in wire connector (included) that is attached to the Black wire in
the fixture. Do not mix wires or change polarity.
D. Pull on each wire lead to make sure connections are secure. Make certain no bare wires are
exposed outside of the wire connectors.
E. To close cover- Carefully arrange wires so they do not get pinched and rotate cover against
channel. Secure cover under housing lances.
F. Proceed to Lamping Instructions below.
7. Lamping
A. DO NOT TOUCH BARE LAMPS WITH BARE HANDS. Oils from your Skin may damage the lamp when it heats up.
B. Remove lamp from box. Hold the lamp by the Pins or with the use of a protective plastic cover (a glove or a plastic bag work well).
C. Install lamps by pushing straight into sockets. Adjust lamp(s) as needed to not touch lens.
D. Replace glass lens by sliding it back into housing until it fully seats within the housing
8. Lamp Removal
A. Allow lamp to cool before handling.
B. Remove the lamp by grasping and pulling straight out from the lamp socket.
C. See the label on the fixture for replacement lamp type information. Maximum 20 watts (BI-PIN base) 120volt Xenon lamp.
Limited Factory Warranty - AFX hereby warranty that this fixture is free from defects in materials and workmanship when installed
and used under normal operating conditions for a period of 2 years from date of purchase. This warranty covers all component parts and
extends only to replacement of defective fixture or components; it does not cover failure due to improper installation,
misuse, mishandling or damage incurred in transit
.
This Warranty does not cover normal lamp replacements.