AFX DEF182400L30D1SN User Manual
Delta flush series, Flushmount led fixture, Safety precautions
Delta Flush Series
Flushmount LED Fixture
Models: DEF182100 / DEF182500
Page 1 of 1
8060816 R0
Safety Precautions
Read all safety precautions and installation instructions carefully
before installing or servicing this fixture. Failure to comply with
these instructions could result in potentially fatal electric shock
and/or property damage.
It is recommended that all wiring be performed by a qualified
electrician. This fixture must be wired in accordance with all national
and local electrical codes.
Do not handle any energized fixture or attempt to energize any
fixture with wet hands or while standing on a wet or damp surface or
in water.
Make sure that the power source conforms to the requirements of the
fixture (see labels on fixture housing).
To reduce the risk of electrical shock, and to assure proper operation,
this fixture must be adequately grounded. To accomplish proper
grounding, there must be a separate ground wire (green) or bare metal
contact (metal conduit) between this fixture and the ground
connection of your main power supply panel.
This fixture is intended to be used for general indoor lighting in dry
or damp locations only.
Assembly Instructions
1.
Preparing for installation
A. Disconnect electrical power before installing or servicing any part of this fixture
B. Remove fixture from carton; remove backpan assembly, diffuser and hardware
kit
C. Install four metal brackets (2) on the diffuser (1) with four screws (3)
D. Thread two screws (5 - provided) into the cross gem bar (6). Leave about ½”
length exposed
E. Install cross gem bar (6) on the junction box (not provided) by securing it with
two (4) screws
2.
Wiring
All wiring must take place inside junction box. Caution: Make sure power is off at fuse or circuit breaker box. Check power
wires for damage or scrapes. If power supply wires are within three inches of LED driver, use wire suitable for at least 90C (194F).
Note: Most dwellings built before 1985 have supply wire rated to 60C. Consult a qualified electrician before installing
A. This unit will not operate properly unless connected to a “grounded” electrical circuit. Electrical shock, over heating, low or no
light output, and shortened lamp life can result if proper grounding is not
done. Securely attach green (or green and yellow) wire to ground supply
wire
B. Using wire nuts (provided), connect white (common) supply wire to
white
fixture lead. Connect black (hot) supply wire to black fixture lead. Do not
mix wires. Pull on each wire lead to make sure connections are secure.
Make certain no bare wires are exposed outside of wire connectors. Note:
fixtures with universal voltage power supplies are pre-wired with a
disconnect. Refer to the included guide for using the disconnect
C. Tuck all connections neatly into junction box
3.
Mounting fixture
A. Align the ceiling pan (7) keyhole slots with screws (5). Insert screws
through the keyhole openings. Twist backpan and secure it by tightening
screws
4.
Mounting diffuser
A. Raise diffuser to ceiling pan and align diffuser brackets with all four
ceiling pan slots
B. Insert diffuser over slots and then rotate 1/8 turn clockwise until diffuser brackets rest in corresponding notches
C. Verify brackets are properly seated in notches by attempting to rotate diffuser. It should not rotate if properly installed.
5.
Power to the fixture can now be restored
Limited Factory Warranty
AFX Inc. hereby warranty that this fixture is free from defects in materials and workmanship when installed and used under normal operating
conditions for a period of 5 years from date of shipment from factory. This warranty covers all component parts and extends only to replacement of
defective fixture or components; it does not cover failure due to improper installation, misuse, mishandling or damage incurred in transit.