beautypg.com

AFX MRF16226QMVSN User Manual

Monroe flushmount, Fluorescent fixtures, Safety precautions

background image

Monroe Flushmount

Fluorescent Fixtures

Model: MRF226QMV

Page 1 of 1

8060726 R0

Safety Precautions

Read all safety precautions and installation instructions carefully
before installing or servicing this fixture. Failure to comply with
these instructions could result in potentially fatal electric shock
and/or property damage.

It is recommended that all wiring be performed by a qualified
electrician. This fixture must be wired in accordance with all national
and local electrical codes.

Do not handle any energized fixture or attempt to energize any
fixture with wet hands or while standing on a wet or damp surface or
in water.

Make sure that the power source conforms to the requirements of the
fixture. (See labels on fixture housing).

Model numbers ending in

MV are designed for use in a 120-277VAC, 60Hz fused circuit (Do
not use on a dimming circuit).
To reduce the risk of electrical shock, and to assure proper operation,
this fixture must be adequately grounded. To accomplish proper
grounding, there must be a separate ground wire (green) or bare metal
contact (metal conduit) between this fixture and the ground
connection of your main power supply panel.

This fixture is intended to be used for general indoor lighting in dry
or damp locations only.

Assembly Instructions

1.

Preparing for installation

A.

Disconnect electrical power before installing or servicing any part of this fixture.

B.

Remove fixture from carton; remove backpan assembly, diffuser and hardware kit.

C.

Thread two screws (1) (provided) into the junction box (not provided). Leave about ½” length exposed.

2.

Wiring
All wiring must take place inside junction box. Caution: Make sure power is off at fuse or circuit breaker box.
Check power wires for damage or scrapes. If power supply wires are within three inches of ballast use wire suitable for
at least 90C (194F). Note: Most dwellings built before 1985 have supply wire rated to 60C. Consult a qualified
electrician before installing.

A. This unit will not operate properly unless connected to a

“grounded” electrical circuit. Electrical shock, over heating, low
or no light output and shortened lamp life can result if proper
grounding is not done. Securely attach green (or green and
yellow) wire to ground supply wire.

B. For wiring ballast power leads and power supply wires

use Ballast disconnect Instructions (provided).

C. Tuck all connections neatly into junction box.

3.

Mounting

A.

Align the backpan (2) keyslots with screws (1). Insert screws (1)
through the keyslot openings. Twist backpan and secure it by
tightening screws.

B.

Insert threaded stem (6) into pre-assembled nut (5) and secure
with nut (7).

C.

Install threaded washer (8) on stem (6).

4.

Lamps

A.

Install compact fluorescent lamps (4) (not provided) into
sockets (5).

5.

Diffuser mounting

A.

Install diffuser (9) on threaded stem (6) and secure it with
square washer (10) and finial nut (11).

6.

Power to the fixture can now be restored.


Limited Factory Warranty
American Fluorescent Corporation hereby warranty that this fixture is free from defects in materials and workmanship when installed and used under
normal operating conditions for a period of 2 years from date of shipment from factory. This warranty covers all component parts and extends
only to
replacement of defective fixture or components; it does not cover failure due to improper installation, misuse, mishandling or damage incurred in
transit.