beautypg.com

Crp series, Fluorescent pendant – AFX CRP418RBMV User Manual

Page 2

background image

CRP Series

Fluorescent Pendant

Models 418/ 618/420/620

Page 2 of 2 8060454 Rev. 7

through the center hole of the mounting bracket. (See Detail B) Once the fixture has been mounted, attach the
hangers to the hooks on the hanger assembly.

B. (See Detail C) Place nipple (16) into open hickey (17) and thread on hexnut (19). Thread top of nipple (16) into

hickey (18) and tighten. Adjust height of bowl by adjusting hexnut (19) height on nipple (16) to proper height to
avoid sagging of the diffuser. Push up on bottom of diffuser to desired tension and adjust with hexnut.

4. Wiring.
Caution:
Make sure power is off at fuse or circuit breaker box. Check power wires for damage or scrapes. If power
supply wires are within three inches of ballast, use wire suitable for at least 90C (194F). Note: Most dwellings built
before 1985 have supply wire rated to 60C. Consult a qualified electrician before installing.

A. This unit will not operate properly unless connected to a “grounded” electrical circuit. Electrical shock, over

heating, low or now light output, and shortened lamp life can result if proper grounding is not done. Securely
attach green (or green and yellow) wire to provided green ground screw.

B. Using wire connectors provided, connect white supply wire to white ballast lead. Connect black hot supply wire

to black ballast lead. Do not mix wires. Pull on each wire to make sure connections are secure. Make certain no
bare wires are exposed outside of wire connectors.

C. Line up the two holes in the canopy (4) with the two screws (1) in the mounting bracket (2). Secure fixture to

screws with the two thumb nuts (7) provided.

5. Lamp Installation (Lamps included on models ending with “SCTD”).

A. For model ending in MV, use only 18 watt fluorescent, quad 4-pin lamps (10). To install, line lamp pins with the

corresponding holes in the lamp socket (13) and push lamp into place until a click is heard. Repeat for each lamp.

B. For models ending in SCTD (See Detail D) usable on dimming circuit with dimmable GU24 base lamps, use

only GU24 base lamps only (26W max.). To install, line up lamp pins with the corresponding holes in lamp
socket and turn clockwise until a click is heard. Repeat for each lamp.

NOTE: BE CAREFUL NOT TO ROTATE PENDANT DURING LAMP INSTALLATION/REPLACEMENT

Limited Factory Warranty
American Fluorescent Corporation hereby warranty that this fixture is free from defects in materials and workmanship when installed and used under
normal operating conditions for a period of 2 years from date of purchase. This warranty covers all component parts and extends only to replacement
of defective fixture or components; it does not cover failure due to improper installation, misuse, mishandling or damage incurred in transit.

DETAIL B