AFX CRP418RBMV User Manual
Crp series, Fluorescent pendant, Safety precautions
CRP Series
Fluorescent Pendant
Models 418/618/420/620
Page 1 of 2 8060454 Rev. 7
DETAIL A
Safety Precautions
Read all safety precautions and installation instructions carefully
before installing or servicing this fixture. Failure to comply with
these instructions could result in potentially fatal electric shock
and/or property damage.
It is recommended that a qualified electrician perform all wiring. This
fixture must be wired in accordance with all national and local
electrical codes.
Do not handle any energized fixture or attempt to energize any
fixture with wet hands or while standing on a wet or damp surface or
in water.
Make sure that the power source conforms to the requirements of the
fixture. (See labels on fixture housing).
Models ending in MV power source 120-277V Non-dimmable
Models ending in SCTD power source 120V (Self Ballasted
dimmable CFL) Usable on a dimming circuit with dimmable lamps
To reduce the risk of electrical shock, and to assure proper operation,
this fixture must be adequately grounded. To accomplish proper
grounding there must be a separate ground wire (green) or bare metal
contact (metal conduit) between this fixture and the ground
connection of your main power supply panel.
This fixture is intended for use as general lighting in dry or damp
locations.
Assembly Instructions
1. Preparing for installation.
A. Disconnect electrical power before installing or servicing any part of this fixture.
B. Unpack and lay out all of the fixture components in a manner that you can see that you have everything that you
need to fully assemble the fixture.
2. Fixture assembly - Lighting fixture is partially assembled
A. Disassemble entire center section; stems (8, 10), threaded nipples (6), swivel (5) and hanger assembly (9).
B. Take the fixture power wires (black and white) and feed them through the nipples (6) and stems (8, 10). Thread
the stem/nipple onto the fitting on top of the socket plate (12) until secure.
C. Please loctite all stems with supplied loctite to prevent stems
from coming undone.
D. Insert the wires through a ¾” nipple at the top of the
socket/ballast plate and through the 16” stem (10). Slide wires
through 1¾” threaded nipple inside the hanger assembly (9)
and thread nipple ¼” into stems.
NOTE: Two 6” and two 12” stems included for desired height
between hanger assembly and canopy.
E. Insert wire through stem (8) and secure stem to ¾” nipple (6).
Slide wires through top swivel (5), canopy (4) and canopy
nut. Loctite and tighten all stems and nipples.
NOTE: It will be easiest to slide the wire through each
stem if the threaded nipples at the top of each item are
removed.
F. (See Detail A) Remove the screw
(21) from the decorative arm (11).
Insert the arm through the opening
with the square hanger on the inside
of the diffuser (15). Reattach the
screw through the decorative cap (20)
and arm and repeat until all 4 arms
have been completed.
3. Fixture mounting.
A. Insert 1 ½” screws (3) through offset cross bar (2) and secure
to junction box in ceiling (not provided). Be sure that the two
screws (1) mounted to the bracket line up with the holes in the
canopy (4), and point towards the floor. Slide supply wires
*MV model shown with 4-pin CFL’s