Safety Precautions
Read all safety precautions and installation instructions carefully
before installing or servicing this fixture. Failure to comply with
these instructions could result in potentially fatal electric shock
and/or property damage.
It is recommended that a qualified electrician perform all wiring. This
fixture must be wired in accordance with all national and local
electrical codes.
Do not handle any energized fixture or attempt to energize any
fixture with wet hands or while standing on a wet or damp surface or
in water.
Make sure that the power source conforms to the requirements of the
fixture. (See labels on fixture housing).
To reduce the risk of electrical shock, and to assure proper operation,
this fixture must be adequately grounded. To accomplish proper
grounding there must be a separate ground wire (green) or bare metal
contact (metal conduit) between this fixture and the ground
connection of your main power supply panel. The green ground
screw location is clearly marked on the fixture housing.
This fixture is intended to be used for general lighting in dry or damp
locations only.
Assembly Instructions
1. Preparing for Installation -
A.
Disconnect electrical power before installing or servicing
any part of this fixture.
B.
Remove light fixture, decorative hardware, isolation
canopy and parts bag from carton
2. Fixture Assembly -
A.
Uncoil coax cable (5) and thread loose end through strain
relief (7) (smaller end toward Pendant fixture).
B.
Temporarily secure strain relief onto coax cable at desired
height by tightening setscrew using hex-wrench provided.
C.
Feed the decorative canopy (6) through coax cable.
D.
Prepare the outer braided wire (-) and insulated conductor
(+) for wiring onto LED driver.
3. Fixture Mounting & Wiring -
Caution: Make sure power is off at fuse or circuit breaker box.
Check power wires for damage or scrapes. If power supply wires are
within three inches of ballast use wire suitable for at least 90C
(194F). Note: Most dwellings built before 1985 have supply wire
rated to 60C. Consult a qualified electrician before installing.
A.
Feed the black and white supply wires, and the green
ground wire into isolation canopy (1) through the off-center
hole.
B.
Fasten the isolation canopy (w/ LED driver affixed) to the
electrical box {not shown} in the ceiling using #8-32
screws (2). [See figure 1]
C.
Thread nipple/hickey assembly into isolation canopy (3)
and secure it from rotating by tightening the jam nut against
the canopy. NOTE: the nipple should extend down 1-3/4”
from the bottom of the isolation canopy.
D.
Wire the primary side (120VAC, 60Hz) of the LED driver
(4) (black and white wires) to the supply wires observing
wire color convention. Connect ground wire to metal
canopy using green ground screw attached to canopy.
E.
Loosen the canopy strain relief (7) set screw using hex-
wrench provided –while holding coax cable and raise
pendant fixture to the ceiling.
F.
Feed coax cable (5) through lower nipple and out through
aperture of hickey coupling (3).
G.
Twist coax cable outer wire braid with blue wire of LED
driver and secure with blue wire nut provided. Repeat this
step for joining the inner conductor with the red wire of the
LED driver.
H.
Insert any protruding wires between decorative canopy and
isolation canopy and raise pendant light to desired height.
I.
Thread canopy strain relief onto bottom of nipple until
tight.
J.
Re-tighten strain relief set screw to secure coax cable and
pendant height.
A.
Restore power at fuse or circuit breaker box.
- LAPL45040BUSN LAPL45040GNRB LAPL45040WHSN KEPL45040WHSN KEPL45040GNSN KEPL45027ASRB KEPL45027AMRB GEPL45027AMRB GEPL45040BUSN GEPL45040WHSN ATPL45027AMSN ATPL45040WHRB ATPL45040WHSN ATPL45027AMRB SXPL45027AMRB SXPL45040BUSN SXPL45040RDRBD1 SXPL45040WHSND1 BEPL45040BUSN BEPL45040RDRB BEPL45040WHSN BEPL45027AMRBD1