beautypg.com

ADTRAN Network Interface Module T1/FT1 User Manual

Wan-t1 n, Rj-48c) c, Dsx-1 (rj-48c) c

background image

NetVanta T1/FT1 + DSX-1 Network Interface Module (NIM) P/N 1202863L1

For more detailed documentation, visit us online at

www.adtran.com

.

Quick Start Guide

®

Quick Start Guide, 61202863L1-13D, November 2006

Copyright © 2006 ADTRAN, All Rights Reserved

I

NSTALLATION

I

NSTRUCTIONS

1.

Remove the power from the unit.

2.

Slide the option module into the option slot until the module is
firmly seated against the chassis.

3.

Secure the pins at both edges of the module.

4.

Connect the cables to the associated device(s).

5.

Complete installation of the base unit.

6.

Restore power to the unit.

For NetVanta modules with outside plant
connections, ensure that all cables are removed
from the module before installing or removing it
from the NetVanta chassis.

NetVanta modules should be installed only in NetVanta
Series products.

WAN-T1 N

ETWORK

(RJ-48C) C

ONNECTION

P

INOUTS

Pin

Name

Description

1

R1

Receive data from the network - Ring 1

2

T1

Receive data from the network - Tip 1

3

Unused

4

R

Transmit data toward the network - Ring

5

T

Transmit data toward the network - Tip

6-8

Unused

DSX-1 (RJ-48C) C

ONNECTION

P

INOUTS

Pin

Name

Description

1

R

Transmit data toward the DTE- Ring

2

T

Transmit data toward the DTE - Tip

3

Unused

4

R1

Receive data from the DTE - Ring 1

5

T1

Receive data from the DTE - Tip 1

6-8

Unused

An optional Dial Backup Interface Module (DIM) is
required for dial backup applications.
For a description of the DBU pinouts, refer to the Quick
Start Guide included with your DIM shipment.

WAN-T1

DSX-1

DBU

S

PECIFICATIONS

Operating
Modes

Frame Relay, Multilink Frame Relay,
PPP, Multilink PPP, HDLC

T1/FT1
Interface

Supported Standards: AT&T TR 62411, AT&T TR 54016,
Bellcore TR.194, ANSI T1.403
Line Rate: 1.544 Mbps ±75 bps
Line Code: AMI or B8ZS
Framing: D4 (SF) or ESF
FT1 Line Rate: DS0 channelized (multiples of 56/64 kbps)
Input Signal: 0 to -36 dB (DS1)
Line Build-Out: 0, -7.5, -15, -22.5 dB (long), 0 to 655 ft
(short)
Connector: RJ-48C
DS0 Assignment: Programmable

DSX-1
Interface

Supported Standards: ANSI T1.102
Line Rate: 1.544 Mbps
DSX Receiver Input Range: -10 dBdsx to +6 dBdsx
Capacity: 1 to 24 DS0s
Line Codes: AMI, B8ZS
DSX-1 interface to PBX
Framing: D4 (SF) or ESF
Line Length: 0 to 655 ft and -7.5 dB
Connector: RJ-48C

Clock Source

Network, internal, and through

Diagnostics

Test Pattern Generation and Detection: QRSS, 511, 2

15

- 1,

2

20

- 1, all ones, all zeros

Network loopbacks (local and remote); responds to both
inband and FDL loop codes (T1 interface only)
Alarm generation and detection
Network and user sets of performance data (15 minutes
and 24 hours)

Compliance

FCC Part 15 Class A, EN 55022 Class A
ACTA/FCC Part 68, IC CS-03
UL/CUL 60950

Physical

Dimensions: 2.75-inch W x 4.25-inch D
Operating Temperature: 0°C to 50°C
Storage Temperature: -20°C to 70°C
Relative Humidity: Up to 95 percent, noncondensing