n

Multi-Unit Entry Stations for Open Voice Intercoms

ARCHITECTS/ENGINEERS’ SPECIFICATIONS:

The intercom system shall be of an open voice, selective
calling type with the ability for two-way communication with
the specified inside stations.

Entrance station shall be available with two to eight call
buttons. Entrance station shall selectively call to the following
inside master stations: C-ML/A, LEM-1DL/C, or LEF-series
master stations.

Entrance panel shall be flush mount with optional weather
resistant hoods available. The entrance panel shall have an
aluminum faceplate, equipped with call buttons and directory
strips. A surface mount box with built-in weather resistant
hood shall be available.

ENTRANCE PANEL KITS (Stock)
LE-GA2

2-Call Entry Panel

LE-GA3

3-Call Entry Panel

LE-GA4

4-Call Entry Panel

LE-GA5

5-Call Entry Panel

LE-GA6

6-Call Entry Panel

LE-GA7

7-Call Entry Panel

LE-GA8

8-Call Entry Panel

S.O.P. MASTER STATIONS
LEM-1DL/C

Master station with manual
OFF button for one entry.
Wall or desk mount
(Multiple masters.
PT-1210N for each master.)

LEF-3L

3-call master with selective
door release (multiple masters OK)

STANDARD PRODUCTS:
GW-002H

Semi-flush mtg. hood (up to 4 buttons)

GW-002HB

Surface mtg. hood (up to 4 buttons)

GW-003H

Semi-flush mtg. hood (5~8 buttons)

GW-003HB

Surface mtg. hood (5~8 buttons)

STOCK MASTER STATIONS:
C-ML/A

Master station with automatic time out

LEF-5

5-call master with selective dr. release

LEF-10

10-call master with selective dr. rel.
master stations.

POWER SUPPLIES:
SKK-620

6V DC, 200mA for C-ML/A masters

PT-1210N

16V AC, 10VA for LEM-1DL/C masters

PS-12C

12V DC, 1A for LEF Systems

LE-GA

n

-SS 0102

SYSTEM LAYOUT EXAMPLE
(with C-ML/A master stations):

2

2

2

2

SKK-620

SKK-620

LE-GA4

C-ML/A

C-ML/A

When using C-ML/A or LEM-1DL/C master stations, each
station must be powered independently with its own power
source. Two room stations with separate power supplies can
be used together with the LEM-1DL/C master stations. A
second C-ML/A can be used, along with the DAK-2S dual
master adaptor kit and separate power supplies.

The system used with the LEF system shall have the
capability of adding individual door stations and multiple
master stations.

System shall be manufactured by Aiphone.

NOTE:
Wiring for door strike and power
source for strike not shown.
Run separate 2 conductor wire from
master to door strike and power.

SKK-620