ViewStat Installation and Wiring
9
ViewStat Communicating Thermostat
Setting the DIP Switch
Set the DIP switch located on the thermostat circuit board (FIG. 4) according to the application needs (see the
DIP Switch Settings table below for details).
The following table shows what each switch corresponds to depending on position. Switch one should be set in
the “OFF Servant” position unless you plan to broadcast readings from remote temperature sensors to other
thermostats in the system when there is no control system in place.
Reassembly
No tools required – line up pins on circuit board with the corresponding terminal blocks. Use your hands to
push the front panel securely to the mounted base.
FIG. 4
Setting the DIP Switch
DIP Switch Settings
Application
Switch
#1
Switch
#2
Switch
#3
Switch
#4
Single Stage Furnace & AC
Servant
Fossil
Single
H/C
Two Stage Furnace & Two Stage AC
Servant
Fossil
Multi
H/C
Roof Top Unit (Two Stage Heat & Two Stage Cool) Servant
Fossil
Multi
H/C
Boiler with AC (Two Transformers)
Servant
Fossil
Single
H/C
Single Stage Heat Pump
Servant
Electric
Single
HT. Pump
Two Multi-stage Heat Pump
Servant
Electric
Multi
HT. Pump
First Stage Radiant Floor Heat,
Second Stage Furnace One Stage of Cooling
Servant
Fossil
Multi
H/C