Additional items for difficult stony soils

Item

Part

Number

Open Centre Tungsten Tip Auger 61.0 mm



70045

Rock Breaker 54.0 mm



70025

Auger extension rods re-enforced 1.0 m



70015

Miscellaneous Items (Installer to supply)

Length of rope – to tie branches or vines temporarily out of the way so that they do not get damaged or
interfere with the augering process.

Duck boards – to prevent soil campaction around the access tube during the installation process.

Measuring tape – to measure to the required depth

Marking pen

2 x 10 litre (2 gallon) buckets – to collect the augered soil and remove it from the site, and to mix the slurry
in.

Notepad and pencil - to record the depth and texture variation throughout the soil profile and any other site
information.

Paint stirrer with electric drill attachment – for mixing the slurry.

Cordless electric drill – to attach to the paint stirrer for mixing the slurry.

Spatula or broad knife – to chip away excess slurry

Slurry Components

Grey cement

Kaolinite (potters clay as fine powder)

Water