beautypg.com

Campbell Scientific Sentek EnviroSCAN Access Tube Installation Guide User Manual

Page 26

background image

Installing EnviroSCAN, EnviroSM ART & Diviner 2000 access tubes

© Sent ek Pt y Lt d

Page 23

depth has been reached. Note: If the access tube spins while augering, engage the metal
“tooth
” on the tripod by turning the lever located on the tripod cylinder.

12. Use the auger cleaning tool to remove the soil from the auger head. Do not empty the

augered soil near the access tube as it may change the infiltration rate of irrigation and
rainfall. Dispose of the soil away from the monitoring site.

13. Select the Heavy duty dolly and re-insert it in the top of the access tube.

14. Turn the lever to make sure that the metal tooth on the tripod cylinder is “disengaged”. Take

the sledge hammer and hit the dolly to drive the access tube further into the pre-drilled hole.

15. When you reach the bottom of the pre-drilled hole, hammering becomes noticeably more

difficult. Remove the dolly.