Campbell Scientific Sentek EnviroSCAN EasyAG SDI-12 Manual v 3.4 User Manual
Page 7

EnviroSMART & EasyAG SDI-12 Probe Manual
Copyright © 1991 – 2003 Sentek Pty Ltd All rights reserved
Page 2
What is the Intelligent Probe Configuration Utility?
The Intelligent Probe Configuration Utility is provided to configure the EnviroSMART and EasyAG
SDI-12 probe interfaces with depth location, normalization values (air and water counts) and calibration
information for each sensor installed on the probe. This information is stored in non-volatile memory,
and is used to produce the calculated value (value that has been processed via the interfaces calibration
formula) from each sensor on the probe.
Communication between the Intelligent Probe Configuration Utility and the EnviroSMART and
EasyAG SDI-12 probe interface is done using the Intelligent Probe Configuration Utility cable from a
computers communication port to the probe interfaces TTL port.
Note: Temperature Sensors are currently not supported by the EnviroSMART and EasyAG SDI-12
probe interface.
Note: Information stored in non-volatile memory will not be lost when power is removed from the
SDI-12 probe interface.
Figure 1: Intelligent Probe Configuration Utility software
Setting the Probe Configuration
The Intelligent Probe Configuration Utility is provided to configure the EnviroSMART and EasyAG
SDI-12 probe interfaces with depth location, normalization values (air and water counts) and
calibration.
Auto-detect Sensors
Auto-detect Sensors will detect all sensors currently installed on the probe. After the sensors are
detected the configuration information (including type of sensor) will be displayed in the Probe
Configuration list.